PaymentL/C,T/T,D/P,Paypal,Money Gram,Western Union
IncotermFOB,CFR,CIF,EXW,FCA,CPT,CIP
Min. Order10 Gram
TransportationOcean,Land,Air,DHL,TNT
PortShanghai port,Qingdao port
Product Attributes
BrandTianfu
Model No.TF-4074
minOrder10 Gram
Supply Ability & Additional Information
Productivity100Ton
Payment TypeL/C,T/T,D/P,Paypal,Money Gram,Western Union
Place of OriginChina
TransportationOcean,Land,Air,DHL,TNT
PortShanghai port,Qingdao port
IncotermFOB,CFR,CIF,EXW,FCA,CPT,CIP
PackagingAs Buyer's Request
Supply Ability50Ton
CertificateISO
Packaging & Delivery
Selling Units:Gram
Package Type:As Buyer's Request
Description
Product Name: SEPHADEX G-50 Synonyms: PDXTM G.F.;Sephadex(R) G-50 Fine;PDX GF 50 (100-300);PDX GF 50 (50-150);SEPHADEX G-50;SEPHADEX G-50 COARSE;SEPHADEX G-50 FINE;Sephadex G-50, Fine beads CAS: 9048-71-9 MF: NULL MW: 0 Product Categories: DNA&RNA Purification;Molecular Biology;Reagents;Gel Filtration Media;Sephadex G-50;Gel Filtration Chromatography;Gel Filtration MediaGel Filtration Media;Protein Chromatography;Sephadex Uses The media used for gel exclusion chromatography include dextran (Sephadex™), polyacrylamide (Bio-Gel P™) and dextran-polyacrylamide (Sephacryl™) and agarose (Sepharose™ and BioGel A™). Each is available with a variety of different ranges of pore size in the beads, permitting separation of macromolecules of different size. A gel with a smaller range of pore sizes (and hence a smaller range over which it can separate macromolecules on the basis of their size) will give a higher resolution; a gel with a wider range will give lower resolution, but will permit fractionation of a larger range of sizes as an initial step when the approximate molecular mass of the enzyme is not known. The particle size of the gel beads (the mesh size) also affects resolution; smaller beads permit higher resolution, but a lower flow rate through the column (and hence a slower separation). The table shows the useful range for the most commonly used gel filtration media - the lower and upper molecular sizes (in kDa) over which they can be used to separate macromolecules. The upper limit is known as the exclusion limit of the gel - the size above which proteins will elute in the void volume of the column. lower limit upper limit dextran gels Sephadex G-50 1.5 30 Sephadex G-75 3 80 Sephadex G-100 4 150 Sephadex G-150 5 300 Sephadex G-200 5 600 polyacrylamide gels Bio-Gel P-10 1.5 20 Bio-Gel P-30 2.5 40 Bio-Gel P-60 3 60 Bio-Gel P-100 5 100 Bio-Gel P-150 15 150 BioGel P-200 30 200 Bio-Gel P-300 60 400 dextran-polyacrylamide gels Sephacryl S-200 5 250 Sephacryl S-300 10 1500 Sephacryl S-400 20 8000 agarose gels Sepharose 6B 10 4000 Sepharose 4B 60 20,000 Sepharose 2B 70 40,000 Bio-Gel A-0.5 10 500 Bio-Gel A-1.5 10 1500 Bio-Gel A-5 10 5000 Bio-Gel A-15 40 15,000 Bio-Gel A-50 100 50,000